Herunterladen Inhalt Inhalt Diese Seite drucken

Advanced Welding (If Activated Under Point 5.4); Equipment Layout; Reset; Stw - Software Versions - Jackle ProPuls 330 Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

17.6 Advanced Welding (if activated under point 5.4)

Here, extra welding parameters can be either activated or deactivated.
With the left dial (pos. 2), the desired special function can be selected (►) and the value can be changed with
the right dial (pos. 5).
I2 Current:
Welding crater ex:
DPuls on:
Arc L.:

17.7 Equipment Layout

Here, required settings for the accessories in manual or robotic welding can be configured.
Setup equipment (manual):
Here, the welding torch currently used and the ground cable can be configured.
With the left dial (pos. 2), the desired special function can be selected (►).
Cooling unit:
Optional – Cooling unit is detected automatically or
compulsory – Cooling unit must be connected
Wire feed:
Optional – Wire feed unit is detected automatically or
compulsory – Wire feed unit must be connected
U/D torch:
Torch with display – not possible at the moment
Missing or optional – Torch is detected automatically or
compulsory – Torch must be connected
Torch:
Set torch type . The following types are possible:
AIR – air-cooled torch, H2O – water-cooled torch
150A, 200A, 250A, 300A, 350A, 400A, 450A, 500A
PP8N / PP12N: Push-pull torch with a length of 8m and 12 m
SCC Cable:
Ground cable + intermediate hose pack length from 1 to 100 m
Robot config. (robot welding):
Only necessary and configurable in combination with a robot control.

17.8 Reset

Here, there are 3 different reset functions.
With the left dial (pos. 2), the desired reset function can be selected (►).
Delete all jobs? – Hereby, only the saved jobs are deleted (ALL JOBS!!).
By pressing the special function button 2, under OK, the confirmation prompt YES or NO appears.
By pressing YES, all jobs are deleted, NO cancels the process.
Factory setting? – Hereby only the welding parameters are reset to the factory settings.
By pressing the special function button 2, under OK,' the confirmation prompt YES or NO appears.
By pressing YES, all data are reset, NO cancels the process.
Reset everything? – Hereby, both jobs and all parameters are reset.
By pressing the special function button 2, under OK,' the confirmation prompt YES or NO appears.
By pressing YES, everything is deleted, NO cancels the process.

17.9 STW - Software versions

Here the software versions that are currently installed on your machine are displayed.
SW Source:
Welding machine main PCB software
Curves:
Welding curve software
FDR 1:
Wire feeder 1 software
FDR 2:
Wire feeder 2 software
Torch:
Display software in the welding torch (if available)
Robot:
Robot interface software (if available)
S/N...:
Serial number of the entire machine (press ENTER / OK again)

17.10 Download / upload

In this menu, you can read and save existing data from the machine, or install new data and parameters in the
machine.
With the left dial (pos. 2), the desired special function can be selected (►) and the value can be changed with
the right dial (pos. 5).
Operating manual
Disabled –secondary power I2 is not active
I2 Standard - secondary power I2 is active with limited parameters Fx
I2 Advanced - secondary power I2 is active with all parameters Fx
Cr. Standard - welding crater function is active with limited parameters Fx
Cr. Advanced - welding crater function is active with all parameters Fx
DP Standard - double pulse function is active with limited parameters Fx
DP Advanced - double pulse function is active with all parameters Fx
Voltage – arc length correction with voltage shown in volts
Wire speed .– arc length correction with wire speed shown in m/min
ProPuls 330,400,500
Page 48

Quicklinks ausblenden:

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Propuls 400Propuls 500Propuls 320 compact

Inhaltsverzeichnis