Herunterladen Inhalt Inhalt Diese Seite drucken

Fx / Parameter Description Of The Welding Processes Mig/Mag - Jackle ProPuls 330 Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

16.4 Fx / parameter description of the welding processes MIG/MAG:

The parameters can be called up using the Fx button and
changed with both dials.
Function:
Selection with the left
Rotating knob (Pos. 2)
Gas pre flow time
Start speed
Start pulse
Start current
Arc length Start
Crater Start time
Start ramp
End ramp
End current
Arc length End
Crater End time
Burn back time
Gas post flow time
Current I2 Start ramp
Current I2
Arc length I2
Current I2 End ramp
Double pulse Start ramp
Double pulse current
Double pulse arc length
Double pulse balance
Double pulse frequency
Double pulse End ramp
Current rise rate
Spot time
Welding ON time
Pause (OFF) time
• Standard crater program:
2 step: The torch trigger is pressed and after the gas pre-flow time has elapsed, the arc is ignited with the
preset hot start current. After the hot-start time is finished, the current slopes down, over the preset start
ramp time, to the preset main welding current I1.
The torch trigger is released , and the current slopes down to the preset end crater-fill current, over the
end-crater ramp time. After the welding crater end time, the arc extinguishes.
After this, the shielding gas flows for the preset gas post flow time.
4 step: The torch trigger is pressed and the arc is ignited with the preset hot-start current. The hot start current
is active all the time the trigger is pressed. When the trigger is released, the current slopes down, over
the preset start ramp time, to the main welding current I1, where it stays.
When the torch button is pressed again , the current slopes down over the end-crater ramp time, to the
preset end crater-fill current. The end crater-fill current is active all the time the trigger is pressed. and
stays at this level. The torch trigger released , and the arc is extenguished. After this, the shielding gas
flows for the preset gas post flow time.
Operating manual
Display text
PRE GAS
0.1s
START SPEED
START PULS
INIT CURRENT
20%
INI. ARC L.
T. INIT CARTER
1.0s
INI SLOPE C.
1.0s
FIN SLOPE C.
1.0s
FINAL CURRENT
-30%
FIN ARC L.
T: FIN CRATER
0.0s
BURN BACK
POST GAS
1.0s
IN SLOPE CYC
0.05s
CYCLE CURR.
20%
CYCLE ARC L.
FI SLOPE CYC
0.05s
IN SLOPE DP
5.5s
DPuls – CURR
50%
DP Arc Len
DPuls - BAL.
DPuls - FREQ.
2.7
FI SLOPE DP
5.1s
100
Slope Job
A/s
SPOT TIME
3.0s
STITCH TIME
1.0s
STITCH PAUSE
1.0s
F
X
Range-
values
Selection
with the
right
rotating knob
(Pos. 8)
0.0 – 2.0s
0
-30 - +30
0
-30 - +30
-50 - +100%
0
-30 - +30
0.0 – 2.0s
0.0 – 2.0s
0.0 – 8.0s
-100 - +50%
0
-30 - +30
0.0 – 2.0s
0
-30 - +30
0.0 – 10.0s
0.0 – 1.0s
-99 - +100%
0
-30 - +30
0.0 – 1.0s
0.5 – 100s
-99 - +200%
0
-30 - +30
0
-40 - +40
0.1 – 5.0Hz
0,1 – 100s
5 – 500A/s
0.0 – 20.0s
0.1 – 8.0s
0.1 – 8.0s
ProPuls 330,400,500
Welding process
Page 43

Quicklinks ausblenden:

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Propuls 400Propuls 500Propuls 320 compact

Inhaltsverzeichnis