38. Error table ERROR CODES:

Error CODE
E02
E11 bis E14
E21 bis E24
E80
E81
E88
E91 / E92
E94 / E95
E96 / E97
E99 - CAN
Error CODE with MC-R PCB
Control box in power source
E71
E73/74/75
E78
E79
Operating manual
Cause
Main voltage to high (>480V) or
main under voltage (<350V)
Temperature sensors 1-4
interruption or short circuit
Wrong machine configuration
inoMIG / tecMIG / conMIG
Wrong Software version in
machine or control box MC
Encoder Motor defective, cable
interruption, wrong motor type set
Wrong configuration in control box,
e.g. 2 wire feeder mode
Faulty data transfer on CAN wiring
Faulty CAN protocol
Communication between wire
feeder (MC control box) and
machine completely interrupted
Cause
Overtemperature on the MC-R
PCB
Faulty data transfer on CAN wiring
Faulty CAN protocol
Encoder Motor defective, cable
interruption, wrong motor type set
Communication between wire
feeder (MC control box) and
machine completely interrupted
MC-R PCB activated but not
installed
tecMIG 450/600
Remedy
Check main voltage
Check wiring of the temperature
sensors, check sensor
Change machine type in the control
box MC
Software update
Check cable and encoder,
check motor type in control box
Check configuration in control box
MC
Check wiring
Check configuration in control box
MC
Intermediate hose pack broken,
connector defective, control box
MC or control board in the machine
defective
Remedy
Check temperature in the control
box
Check wiring
Check configuration in control box
Check cable and encoder,
check motor type in control box
Intermediate hose pack broken,
connector defective, control box
MC or control board in the machine
defective
Deactivate MC-R Option