Herunterladen Inhalt Inhalt Diese Seite drucken

Material Strength / Welding Current / Wire Speed; Left Dial (Left Display); Trigger Mode 2-Step / 4-Step / 2-Step Crater-Fill / 4-Step Crater-Fill - Current I2 / Spot / Stitch - Jackle ProPuls 330 Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

16.1 Material strength / welding current / wire speed

A
• Material thickness:
• Welding current:
• Wire speed:
Repeatedly press the button to select the desired function.
The respective LED illuminates.
The value can be set with the left dial (pos. 2)
NOTE: The adjustment ranges vary depending on the welding process and the material.

16.2 Left dial (left display)

With this dial, the selected active parameter material thickness / welding current or wire speed can be
adjusted.
Furthermore, the functions in the text display (left half of the display) can be changed.
16.3 Trigger mode 2-step / 4-step / 2-step crater-fill / 4-step crater-fill – current I2 / Spot
/ stitch
Repeatedly press the button to select the desired function.
• 2-step
• 4-step
• Spot
welding
• Stitch
LED flashes
Operating manual
Possible range from 0.6 to 20mm; in increments of 0.1mm
A
Possible range from 10 to 330/400/500A in increments of 1A
Possible range from 1.2 to 25mm; in increments of 0.1m/min
Press and hold the torch trigger to weld.
Release the torch trigger and the welding process ends.
Press and release the torch trigger to weld.
Press and release the torch trigger and the welding process
comes to an end.
Press and hold the torch trigger to weld.
The welding current flows for a preset time. Afterwards, the welding process
ends automatically. Release the torch trigger.
To repeat, press and hold the torch trigger again.
To adjust the welding spot time, press the Fx button and set the welding spot
time.
Press and hold the torch trigger to weld.
The welding current flows for a preset welding time. Afterwards, the welding
process ends automatically. After a preset pause time, the welding process
starts again for the duration of the preset welding time. This process is repeated
until the torch trigger is released.
To adjust the welding/pause time, press the Fx button and set the welding spot
time.
ProPuls 330,400,500