System konfigurieren
2.3 Konfigurationsdatei "basesys.ini"
[LLDP]
; These variables en/disable the LLDP protocol on X120/X127
; and X130, resp.
;InternalLldpEnabled=0
;ExternalLldpEnabled=1
[LinuxBase]
; Keep size of /var/log/messages around this value
; (not followed exactly for performance reasons)
LogfileLimit=102400
; Protocol/Port pairs to open in the firewall
; (e.g., TCP/5900, UDP/514, ...)
;FirewallOpenPorts="TCP/5900 TCP/102"
; If there is only one Ethernet interface, it's used by
; default as an external (company) network. Alternatively,
; usage as automation net (TCU boot support etc.) is possible
; by setting NetworkModel to "automation". (Only NCU, Service
; and PCU20A variants!)
;NetworkModel=automation
; DisableSubsystems can be used to skip certain CFSes (= subsystems)
; a list of multiple names (separated by spaces) is possible
; a simple name means all CFSes with this name, an absolute path
; (e.g.,/siemens/sinumerik/nck) exactly this one CFS with
; the special value "ALL", all subsystems can be disabled
;DisableSubsystems=nck
; Directory for OEM netboot files (served by tftp to diskless clients)
NetbootDirectory=/oem/common/netboot
; Properties of local time zone: names, offset, start and end day
; Some examples:
34