e) User codes
The combination lock can store up to 110 user codes (100 codes for output #1 and 10 codes
for output #2).
The following section provides an introduction on how to use codes to enable the combination
lock outputs (e.g. to release a door opener), including a number of examples.
We recommend that you create a table to record all access data (including code num-
bers, user codes and user names for outputs #1 and #2).
This will help you to monitor registered users and access permissions.
It will also make it easier to delete users and the corresponding user codes.
Saving a user code:
• The combination lock must be in programming mode (see section 12. a) for details).
• Enter the programming code for output #1 or #2:
Output 1
Output 2
• Enter a memory number.
.....
.....
• Enter the desired 4 - 8 digit user code.
Important!
When the "Auto entry" feature is enabled (see section 12. m), all codes must be the
same length (e.g. if the master code is 5 digits, the user codes must also be 5 digits).
• Press the
button to confirm your entry. The combination lock will beep twice and the mid-
dle LED will flash two times to indicate that the code has been saved.
• You can now create another user (press number
#2).
• When you have finished adding all users, press
12. a) for details).
82
100 user codes for output 1
10 user codes for output 2
for output #1 or number
to exit programming mode (see section
for output