Screw terminal 14 ("DOOR SENS"): Connection for door sensor
When you connect a door sensor (with an NC contact), the combination lock can monitor wheth-
er the door is open or closed.
If the input is not used, it must be connected to the minus/-/GND contact (screw termi-
nal 13).
For this reason, terminals 13 and 14 are connected with a small wire bridge when the
product is shipped.
If you wish to connect a sensor, remove the wire bridge between terminals 13 and 14.
The following functions are available when you connect a door sensor:
• Automatic relocking
You can set output #1 to be activated for 1 - 999 seconds. If output #1 is activated with a valid
code and the door is opened and closed, the activation period (and therefore output #1) will
be automatically reset to lock the door.
This prevents people from opening the door because the activation period has not elapsed.
• Break-in alarm
The combination lock sets off an alarm if someone attempts to open the door without entering
a valid code (or without using the door opener connected to terminal 12).
The alarm will sound for 60 seconds and can be stopped by entering the user code (see sec-
tion 12. j) for details on how to set the user code).
• Open door alarm
You can set output #1 to be activated for 1 - 999 seconds so that the door stays open for a
preset duration.
If the door is still open when the preset period has elapsed, the combination lock will set off
an alarm (see section 12. p) for details).
70
Magnetic
sensor