Herunterladen Inhalt Inhalt Diese Seite drucken

Electrical Connection - Atlantic Explorer Installations- Und Bedienungsanleitung

Brauchwasserwärmepumpe
Vorschau ausblenden Andere Handbücher für EXPLORER:
Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

ELECTRICAL CONNECTION

Be sure to turn off the power before removing the cover, to prevent
any risk of injury or electric shock.
Upstream of the appliance, the electrical installation must have
an all-pole cut-out device (30 mA residual current device)
compliant with the local installation rules in force.
Earthing is mandatory. A special terminal marked
is provided for
this purpose.
In France, it is strictly prohibited to connect a product equipped
with a cable with a plug.
SERVICING – MAINTENANCE - TROUBLESHOOTING
Drainage: Switch the electric power supply and cold water off,
open the hot water taps then operate the drainage valve of the
safety device.
The pressure relief valve drainage device must be activated on
a regular basis (at least once a month) in order to remove limescale
deposits and to check that it is not blocked.
If the power cable is damaged, it must be replaced by the
manufacturer, its customer service or a professional with similar
qualification to prevent any hazards.
Maintenance must only be performed according to the
manufacturer's recommendations.
This manual is available from customer services (address and
contact details at the back of the manual).
FLAMMABLE REFRIGERANT FLUID
Any work procedure which affects safety must only be performed
by competent people (see the maintenance section).
Inhaltsverzeichnis
loading

Inhaltsverzeichnis