The ground wire of the cable must absolutely be connected to earth.
A special terminal which is marked with
purpose. Make sure to turn off the power before removing the cover
to prevent any injury or electric shock.
Upstream of the appliance, the electrical installation must have an
all- pole cut-out device (circuit-breaker, fuse) in accordance with the
applicable local installation rules (30 mA earth-leakage circuit-
breaker). Never provide direct power supply to the heating
component.
MAINTENANCE – SERVICING - TROUBLESHOOTING
Drainage: Turn off the power and the cold water supply, open the hot
water faucets and then open the drain valve of the safety unit. The
drainage system of the pressure reducing device should be operated
periodically (at least once a month). This will eliminate limescales
and ensure that it is not blocked.
If the power cable is damaged, it must be replaced by the
manufacturer, its customer service or a professional with similar
qualification to prevent any hazards. Refer to the wiring diagrams in
section "Electrical connection" - "Installation".
The operating instructions for this appliance can be obtained by
contacting the customer service (contact details will be found at the
end of the manual).
36

ELECTRICAL CONNECTION