Presentation
3. Menu
3.1. Consumption
This menu allows you to view estimated consumption:
• the energy consumption in kWh for hot water production, for the current month, the previous month,
the current year and the previous year since set-up
• the percentage of heat pump operation
If the date and times are not entered (e.g. due to a power outage), the energy consumptions will not
be counted.
3.2. Absence
This menu can be used to set an absence:
• continuous from the current date
• up to a programmed date. On your return, the water in the tank will be hot.
During this absence period, the water temperature will be kept above 15 °C.
An anti-legionella cycle is run if you are absent for more than 2 days, starting 24 hours before your return.
The function can be stopped at any time by clicking the OK button.
3.3. Boost
This function temporarily increases hot water production:
• once, until the tank is full
• for several days (up to 7 days)
The heat pump and the electric heating element start up at the same time, at a setpoint of 62 °C.
Boost mode takes priority over the other modes. When the set period expires, the water heater will return
to its previous mode.
3.4. Setpoint management
This function is used to select the mode:
• Eco+: the water heater autonomously programs consumption to adapt to the user's needs, and save
energy while guaranteeing comfort. In this mode, the user has no control over the setpoint and it is not
visible on the HMI. The water heater automatically adjusts the setpoint based on the usage.
• Manual: the user can choose the temperature at which the water is heated, between 50 °C and 62 °C
(or 45 °C and 62 °C).
3.5. Parameters
3.5.1. Language
This menu is used to select the display language.
3.5.2. Date/Time
This menu is used to correct the time: if the power is cut for more than 5 minutes, it may be necessary to
update the date and time.
Installation
Use
Maintenance
Warranty