3.5.3. Heating time slot (time programming)
This parameter defines the permissible time slots for starting the heat pump and the electric backup
in accordance with the hot water requirements. It can be configured if there is no connection to the off-peak
signal, or to the PV own consumption signal.
The configuration is made for each day of the week. A day must include between one and three time slots
totalling at least 8 hours of heating. Settings are made in 15-minute increments.
3.5.4. Electric backup
This menu is used to set the electric heating element authorisation time:
• as little as possible: only outside the heat pump's operating range or in the event of a heat pump fault
• to secure the quantity of hot water: in addition to the heat pump to guarantee a sufficient volume
of hot water
3.5.5. WIFI
This unit can be connected and controlled remotely using the Cozytouch app via WIFI (WIFI 2. 4G: 2400 MHz
to 2483.5 MHz)
To connect your appliance to the internet, download the application from the App Store or the Play Store and
follow the instructions.
During the process, you will need to scan the QR code on the appliance.
3.5.6. Manual
The QR code displayed on the screen can be used to access the online manual.
3.5.7. Expert access
This menu provides access to the advanced information, settings and test functions.
See the section on "Accessing the Expert menu and Emergency mode" in the User section.
Caution! These settings are reserved for qualified personnel.
4. Accessing the Expert menu and Emergency mode
To access the Expert menu:
Menu
Parameters
Expert access
4.1. Installation type
See installation section "10.3.1. Installation type".