Herunterladen Inhalt Inhalt Diese Seite drucken

Connecting The Individual Control To The System - Bosch Src 100 Rf Installations- Und Bedienungsanleitung

Einzelraumregelung
Inhaltsverzeichnis
Fig. 4
Example of wall hung gas condensing boiler; individual control
radiator
Fig. 5
Example of wall hung gas condensing boiler; individual control
radiator
Further settings are required depending on the selected control type.
The control type Single room-dependent calculates the flow
temperature automatically ( Chapter 6.4) and does not require any
heating curve settings in comparison to the Outside temp.-
compensated control type.
The maximum heating circuit temperature for heating mode or for a
possible cooling mode, the minimum flow temperature and the distance
to the dew point must be set in all cases.
For hybrid applications (Chapter 3.1.1), only set the weather-
compensated or outdoor temperature with base point control type and
carry out manual heating curve settings.
SRC 100 RF – 6721856014 (2024/11)
▶ Activate or deactivate automatic hydraulic balancing
( Chapter 6.7).
The function is only possible in combination with individual control
radiator.
0010047131-001
Fig. 6
Example of wall hung gas condensing boiler; individual control
radiator
▶ Activate or deactivate temperature monitoring ( Chapter 6.5).
The function is only possible in combination with underfloor heating
individual control and control type Single room-dependent.
0010047132-001
Fig. 7
Example heat pump individual control underfloor heating
system
4.2.2

Connecting the individual control to the system

The smartphone (App EasyService) is connected directly to the system
(K 30 RF/K 40 RF) via WLAN.
▶ In system controller UI 800 select the Configure Single Room
Control menu.
▶ Select connection to individual control.
In combination of a K 40 RF with a wall mounted condensing boiler
(system operation UI 800, software version lower than NF49.09) or a
heat pump (system operation UI 800, software version lower than
NF47.11), the menu Connection to individual control is not displayed. In
this case:
▶ Open the WLAN hotspot via the buttons on K 40 RF ( Instruction
K 40 RF) and scan the QR code with the App EasyService directly
from K 40 RF.
Commissioning
0010047139-002
0010048863-001
57