FAULT
The appliance has been tested before being
put into service.
The information provided below is intended
to assist in the identifi cation and correction of
any anomalies and malfunctions which might
occur during use.
The user can solve some of these problems
himself, but for others specifi c technical
knowledge or skill is required, and so they
must only be carried out by qualifi ed staff with
recognised experience acquired in the specifi c
sector of operation.
Faults
Smell of gas
The pilot light does not
ignite
The pilot light goes out
The fl ame is yellow
Burner control knob is
stiff
3320091_ut_GB
FAULT
TROUBLESHOOTING
agents or headquarters, which can be
found in the contacts section of the website
www.angelopo.com.
Causes
Occasional leak because
fl ame has gone out.
The spark ignition devices
are not working
Air in pipelines due to long
period out of use
The thermocouple has not
warmed up enough
Burner dirty, heat exchange
pipes clogged, condensation
drips
Gas control valve
malfunction
NOTE
:
For any need, please contact Angelo Po's
Turn off the gas supply tap and
ventilate the room
Check that the ignition devices
are in good working order.
Light by hand with a naked light.
NOTE: Contact the
after-sales service.
Make more attempts to light the
Make more attempts to light the
NOTE: Contact the
after-sales service.
NOTE: Contact the
after-sales service.
ENGLISH
Remedies
fl ame
fl ame