REPLACING PARTS
To carry out this operation, proceed as follows.
)
Turn off the gas supply tap.
Pull off the knob (A).
)
Undo the screws (C) and remove the control
)
panel (B).
Unscrew the nozzle (D) and replace it with the
)
one suitable for the type of gas in use (see ta-
ble at back of manual).
Replace the control panel (B) and the knobs
)
(A) on completion of the operation.
REPLACING THE PLATE BURNER PILOT LIGHT NOZZLE
To carry out this operation, proceed as follows.
)
Turn off the gas supply tap.
Pull off the knob (A).
)
Undo the screws (C) and remove the control
)
panel (B).
Unscrew the union (D).
)
Remove the nozzle (E) and replace it with the
)
one suitable for the type of gas in use (see ta-
ble at back of manual).
Retighten the union (D).
)
Replace the control panel (B) and the knobs
)
(A) on completion of the operation.
EQUIPMENT DECOMMISSIONING, DEMOLITION AND DISPOSAL
NOTE
: Read the following section of
the "user instruction manual" carefully be-
fore replacing any part:
– Hazards and safety provisions during decom-
missioning.
When decommissioning the appliance, a set
of procedures should be carried out to ensure
that the appliance and its components are not
a hindrance and are not easily accessible.
To ensure that the appliance cannot constitute
hazards for people or the environment, all ener-
gy sources (electricity, etc.) must be disconnect-
ed and rendered unusable, and any liquids pres-
ent must be drained (lubricants, fl uids, etc.).
3320091_inst_GB
REPLACING THE PLATE BURNER NOZZLE
A
C
B
A
C
B
Place the appliance in a suitable area which is
not easily accessible, with barriers to prevent
anyone from accessing it.
When scrapping, sort all components by chem-
ical characteristics and dispose of them sepa-
rately in accordance with the relevant legal re-
quirements.
IMPORTANT: Do not dump non-bio-
degradable products, lubricating oils, and
non-metallic components (rubber, PVC, re-
sins, etc.) in the environment. Dispose of
them in compliance with the relevant laws.
ENGLISH
C
D
C
E
D
17