In rare cases, external temperatures over 15°C can result in a blockage in the flue gas system. As the
temperature difference between the flue gas system and the external air is too low, too little discharge
pressure is built up in the flue gas channel. The flue gases are not dissipated. A so-called pilot fire, which
produces a great deal of heat in a short time, can under some circumstances clear the blockage.
Proceed as follows:
1.
Fully open the flue gas valve
2.
Loosely roll together 2 to 4 sheets of newspaper
3.
Open fire door
4.
Ignite newspaper and hold in the smoke outlet
If the blockage is not cleared despite several pilot fires, you should refrain from starting a fire in the fire-
place. In areas with frequent severe weather conditions, installing a flue gas fan can provide a remedy.
12.6 Preparing the System
Proceed in the specified sequence when preparing your system.
1.
Remove cold ash from the firebox (see Section 14)
2.
Clean ceramic glass
3.
Prepare the fuel
4.
Set up firing module
5.
Fully open combustion air valve
6.
Fully open flue gas valve
7.
Ensure there is a supply of combustion air
8.
Fully open air grille on the casing
12.7 Ignition
Proceed in the above sequence when igniting:
1.
Fully open the convection air damper and the combustion air damper, if present on your system.
→ Pull out both sliders completely.
2.
Check the correct setting of all operating elements (if available on your system). The smoke damper
and the air regulator must be fully open.
3.
Switch off any mechanisms that extract ambient air (extractor hoods, ventilation systems, central dust
evacuation units etc.).
Instruction Manual
Each appliance has a different firebox and therefore dif-
ferent flow relationships. To achieve the correct combus-
tion with good emissions the wood must be placed in the
appliances in the following way.
Fireplace
Axinit Front S
Larimar Front S
ECO 720
35
Situation
2
1