17 Troubleshooting
The chimney draught is inadequate and/or smoke spreads into the room. Check the following:
•
The fireplace door is closed.
•
The smoke regulator* is open.
•
The chimney flue is pre-heated.
•
The combustion air regulator* and the combustion air control are open.
•
The CMV (controlled mechanical ventilation) * in the kitchen has been cut.
•
The CMV * in the toilets has been cut.
•
The wood for the fire is of good quality.
•
No unauthorized fuel is being used.
If all the above conditions are met, you should consult your dealer.
The room is inadequately heated. Check the following:
•
The convection air intake vents* are open.
•
The hot convection air outlet vents* are open.
•
The fireplace door is closed.
•
The convection air regulator* is open.
•
The convection fan* is operating correctly.
•
The smoke regulator* is at least half closed
•
The combustion air control * is at least half closed.
•
The fire is burning with bright flames .
If the problem persists, you should consult your dealer.
.... The fire burns too quickly and cannot be regulated. Check the following:
•
The fireplace door is closed.
•
The smoke regulator* is at least half closed
•
The combustion air control * is at least half closed
If the problem persists, you should consult your dealer.
.... Soot builds up very quickly on the ceramic glass. Check the following:
•
The wood for the fire is of good quality.
•
The smoke regulator* is at least one third to a half closed
•
The combustion air regulator* is open in line with operating conditions (pages 13 - 17).
•
The combustion air control * is open in line with operating conditions (pages 13 - 17).
If the problem persists, you should consult your dealer.
*if the system is fitted with one