17 Troubleshooting

The chimney draught is inadequate and/or smoke spreads into the room. Check the following:
The fireplace door is closed.
The smoke regulator* is open.
The chimney flue is pre-heated.
The combustion air regulator* and the combustion air control are open.
The CMV (controlled mechanical ventilation) * in the kitchen has been cut.
The CMV * in the toilets has been cut.
The wood for the fire is of good quality.
No unauthorized fuel is being used.
If all the above conditions are met, you should consult your dealer.
The room is inadequately heated. Check the following:
The convection air intake vents* are open.
The hot convection air outlet vents* are open.
The fireplace door is closed.
The convection air regulator* is open.
The convection fan* is operating correctly.
The smoke regulator* is at least half closed
The combustion air control * is at least half closed.
The fire is burning with bright flames .
If the problem persists, you should consult your dealer.
.... The fire burns too quickly and cannot be regulated. Check the following:
The fireplace door is closed.
The smoke regulator* is at least half closed
The combustion air control * is at least half closed
If the problem persists, you should consult your dealer.
.... Soot builds up very quickly on the ceramic glass. Check the following:
The wood for the fire is of good quality.
The smoke regulator* is at least one third to a half closed
The combustion air regulator* is open in line with operating conditions (pages 13 - 17).
The combustion air control * is open in line with operating conditions (pages 13 - 17).
If the problem persists, you should consult your dealer.
*if the system is fitted with one