Assembly of internal and external irrigation system (optional)

REF 1777
A
A) Attach open end of the tube set (REF 1706) to the single out branch of the Y-connector (optional, REF 1777).
B) Connect a 16 cm piece of tube (optional, REF 1773) to each of the branching tubes of the Y-connector.
C) Connect one of the 16 cm pieces of tube, that branch out of the Y-connector, with the internal cooling tube of
the contra angle (delivered together with the contra angle, REF 39116).
D) Connect the second piece of tube that branches out of the Y-connector with the external cooling pipe of the
contra angle (welded on laterally to the contra angles head).
E
E) Both 16 cm pieces of tube are now connected to the cooling system of the contra angle.
F) Secure a white tube clips (included with the contra angle, REF 1881) to each of the short tube pieces.
G) Secure tube clips to the contra angle.
H) Contra angle with attached tube clips.
REF 1873
I)
Fix a gray clip (optional, REF 1873) to the tube set leading to the Y-connector.
J)
Fix tube set with the gray clip to the motor cable.
K) Motor cable with ready attached tube set to the motor cable. Secure further gray clips to the motor cable if
needed.
L) Tube set routing with Y-connector for internal and external cooling of the instrument.
10
B
F
REF 1881
I
C
G
J
Essential accessories for internal cooling:
REF 1777
REF 1873
Y-connector
Motor cable clips
MD 11, V2.0, Operating Instructions, REF 31665, V22/17
D
K
REF 1773
16 cm connection tubes
MD 11
H