10.4 BACnet Parameter-Liste
Type
Section
BACNet
Binary
Unit status 0
Alarms
1
values
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24 ÷ 31
32
33
34
35
36 ÷ 39
40
41
42
Remote
43
44
control
P.I.V.
Unit status 0
Analog
Unit status 0
1
values
2
3
4
5
Inputs
6
7
8
9
10
11
12
13-15-17-19-
21-23-25-27
14-16-18-20-
22-24-26-28
Remote
29
30
control
31
32
33
34
35
36
37
38
"humiFog direct" +0300073DE rel. 1.4 - 29.03.2022
Unit request from supervisor zone 1
Unit request from supervisor zone 2
Setpoint zone 1 (humidity)
Setpoint zone 1 (temperature)
Setpoint limit zone 1 (humidity)
Setpoint limit zone 1 (temperature)
Setpoint zone 2 (humidity)
Setpoint zone 2 (temperature)
Setpoint limit zone 2 (humidity)
Setpoint limit zone 2 (temperature)
Parameter
Unit on/off
Circuit breaker intervention
High pressure switch intervention
High pressure
Low pressure
High pressure on bypass
High pressure on bypass
High temperature on bypass
High temperature on bypass
Low pressure on bypass
Zone drain valves error
Expansion offl ine
Warning high temperature on bypass
Retain memory error
Retain memory writes error
Main probe 1 error
Limit probe 1 error
Main probe 2 error
Limit probe 2 error
Low pressure trasducer error
Bypass temperature probe error
High pressure transducer error
Missing model
Water treatment system alarm
Wireless probe offl ine 1 ÷ 8
Main probe 1 from wireless error
Limit probe 1 from wireless error
Main probe 2 from wireless error
Limit probe 2 from wireless error
Unit 1 ÷ 4 alarm
Change oil
Maintenance
Maintenance required
Alarms reset
Unit on/off from supervisor
Unit status
0: OFF BY KEYB
5: STAND BY
1: OFF BY DIN
6: PRODUCTION
2: OFF BY SV
7: ALARM
3: OFF BY SCHED 8: FILL
4: STARTUP
9: WASH
Request zone 1
Request zone 2
Production zone 1
Production zone 2
Water consumption 1
Water consumption 2
Main probe 1
Main probe 2
Limit probe 1
Limit probe 2
Pressure on bypass
Pressure on mail line
Bypass temperature
Humidity from wireless probe 1 ÷ 8
Temperature from wireless probe 1 ÷ 8
Unit request from supervisor zone 1
Unit request from supervisor zone 2
Setpoint zone 1 (humidity)
Setpoint zone 1 (temperature)
Setpoint limit zone 1 (humidity)
Setpoint limit zone 1 (temperature)
Setpoint zone 2 (humidity)
Setpoint zone 2 (temperature)
Setpoint limit zone 2 (humidity)
Setpoint limit zone 2 (temperature)
Variable
Regulation.SVReq_1
Regulation.SVReq_2
RegCfg_1.SetP_hum
RegCfg_1.SetP_temp
RegCfg_1.SetPLim_hum
RegCfg_1.SetPLim_temp
RegCfg_2.SetP_hum
RegCfg_2.SetP_temp
RegCfg_2.SetPLim_hum
RegCfg_2.SetPLim_temp
Variable
UnitOn
Al_CircBreaker.Active
Al_HiPSwitch.Active
Al_HiP.Active
Al_LoP.Active
Al_HiPByPassBlk.Active
Al_HiPByPass.Active
Al_HiTByPassBlk.Active
Al_HiTByPass.Active
Al_LoPByPass.Active
Al_Drain.Active
Al_ExpOffl ine.Active
Wr_HiTByPass.Active
Al_Retain.Active
Al_RetainWrite.Active
Al_MainPrb_1.Active
Al_LimPrb_1.Active
Al_MainPrb_2.Active
Al_LimPrb_2.Active
Al_PressByPass.Active
Al_TempByPass.Active
Al_Press.Active
Al_MissModel.Active
Al_WTS.Active
Al_WPrb_1 ÷ 8.Active
Al_WPrbMain_1.Active
Al_WPrbLim_1.Active
Al_WPrbMain_2.Active
Al_WPrbLim_2.Active
Al_NetUnit_1 ÷ 4.Active
Al_Maint_50.Active
Wr_Maint_1000.Active
Al_Maint_3000.Active
Alarms.AlrmResBySV
OnOff _Status.SVOn
UnitStatus
10: MANUAL MODE
11: READY BACKUP
12: SWITCH OFF
ReqMsk_1
ReqMsk_2
Prod_1
Prod_2
WProd_1
WProd_2
MainPrb_1
MainPrb_2
LimPrb_1
LimPrb_2
PressByPass
Press
TempByPass
Inputs_WPrbs.WirelessPrbVal_1
÷ 8.Hum
Inputs_WPrbs.WirelessPrbVal_1
÷ 8.Temp
Regulation.SVReq_1
Regulation.SVReq_2
RegCfg_1.SetP_hum
RegCfg_1.SetP_temp
RegCfg_1.SetPLim_hum
RegCfg_1.SetPLim_temp
RegCfg_2.SetP_hum
RegCfg_2.SetP_temp
RegCfg_2.SetPLim_hum
RegCfg_2.SetPLim_temp
32
Size Min. Max. Def.
UoM
2
0
100
0
[%]
2
0
100
0
[%]
2
0
100
50
[%rh]
2
50
[°C]/[°F]
2
0
100
50
[%rh]
2
50
[°C]/[°F]
2
0
100
50
[%]
2
50
[°C]/[°F]
2
0
100
50
[%]
2
50
[°C]/[°F]
Min. Max. Def.
UoM
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
0
1
0
1
0
12
0
100
[%]
0
100
[%]
0
100
[%]
0
100
[%]
[Kg/h]/[lb/h]
[Kg/h]/[lb/h]
[%rh]/[°C/°F]
[%rh]/[°C/°F]
[%rh]/[°C/°F]
[%rh]/[°C/°F]
[bar]/[psi]
[bar]/[psi]
[°C]/[°F]
[%rh]
[°C]/[°F]
0
100
0
[%]
0
100
0
[%]
0
100
50
[%rh]
50
[°C]/[°F]
0
100
50
[%rh]
50
[°C]/[°F]
0
100
50
[%]
50
[°C]/[°F]
0
100
50
[%]
50
[°C]/[°F]
Dir.
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Tab. 10.b
Dir
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
RW
RW
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
Tab. 10.c