Herunterladen Inhalt Inhalt Diese Seite drucken

IFM Electronic ecomat 100 CR2530 Original-Programmierhandbuch Seite 275

Inhaltsverzeichnis

Werbung

ifm
Programmierhandbuch
ecomatmobile
Anhang
Index
S-Idx
Parameter name
0x1
Short circuit OUT00...OUT07
0x2023
0x0
Output – open circuit
0x1
Open circuit OUT00...OUT07
0x2024
0x0
Output – overload
0x1
Overload OUT00...OUT01
0x2025
0x0
Input analog – overcurrent
0x1
Overcurrent IN00...IN03
0x2030
0x0
Input resistor
0x1
Resistance IN04
0x2
Resistance IN05
0x2040
0x0
System supply voltage VBBS
0x1
VBBS
0x2041
0x0
Output supply voltage
0x1
VBB1
0x2
VBB2
0x2050
Device temperature
0x20F0
Node ID
0x20F1
Node ID
0x20F2
Baud rate
0x20F3
Baud rate
0x20F4
Autostart
0x6000
0x0
Binary input
Largest sub-index supported
SmartController (CR2530, CR2532) Laufzeitsystem V03.02
Data type
Default
ro
USINT
ro
USINT
ro
USINT
ro
USINT
ro
USINT
ro
USINT
ro
USINT
ro
USINT
ro
UINT
ro
UINT
ro
USINT
ro
USINT
ro
USINT
ro
UINT
ro
UINT
ro
INT
rw
USINT
rw
USINT
rw
USINT
rw
USINT
rw
UINT
ro
USINT
275
Details
0
0 = normal
channels (bit coded)
1 = short circuit
0b---- ---X = OUT00
0b---- --X- = OUT01
0b---- -X-- = OUT02
0b---- X--- = OUT03
0b---X ---- = OUT04
0b--X- ---- = OUT05
0b-X-- ---- = OUT06
0bX--- ---- = OUT07
1
Largest sub-index supported
0
0 = normal
channels (bit coded)
1 = open circuit
0b---- ---X = OUT00
0b---- --X- = OUT01
0b---- -X-- = OUT02
0b---- X--- = OUT03
0b---X ---- = OUT04
0b--X- ---- = OUT05
0b-X-- ---- = OUT06
0bX--- ---- = OUT07
1
Largest sub-index supported
0
0 = normal
channels (bit coded)
1 = overload
0b---- ---X = OUT00
0b---- --X- = OUT01
1
Largest sub-index supported
0
0 = normal
channels (bit coded)
1 = overcurrent
0b---- ---X = IN00
0b---- --X- = IN01
0b---- -X-- = IN02
0b---- X--- = IN03
2
Largest sub-index supported
0
0...30 000
IN04 resistance [Ohms]
0
0...30 000
IN05 resistance [Ohms]
1
Largest sub-index supported
0
VBBS voltage [mV]
2
Largest sub-index supported
0
VBB1 voltage [mV]
0
VBB2 voltage [mV]
0
temperature [°C]
124
1...125
node ID
[!] value(0x20F0) != value(20F1)
124
1...125
node ID
[!] value(0x20F0) != value(20F1)
baud rate
[!] value(0x20F2) != value(20F3)
baud rate
[!] value(0x20F2) != value(20F3)
0
nicht benutzt
0x02
Binär-Eingänge
Größter unterstützter Sub-Index = 2
2015-03-26
Integriertes E/A-Modul: Beschreibung

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ecomat 100 cr2532

Inhaltsverzeichnis