14 Functions with extended selection
14.1 MODE function (Mod)
2-Step/4-step/spot – crater mode:
Use the "−" button to switch between 2-step (2) and 4-step (4) mode. (Left-hand display shows 2 or 4)
Use the "+" button to switch between normal operation ( − ), spot (S) or crater (C) welding. (Right-hand
display shows − or S or C)
14.1.1 Automatic or manual welding mode
Display: "Mod":
Press and hold the "−" button to switch between automatic (A) and manual (H) mode (middle display shows
A or H).
14.2 Job function
14.2.1 Access a single job
Repeatedly press the arrow button until 'Job' appears on the display. Use the "+" or "−" button to select the
relevant job number and confirm this using the arrow button. The job, e.g. no. 2, is selected (= appears on
the display). Note: =
14.2.2 Several jobs in sequence
It is possible to store several jobs in sequence and to switch between the individual jobs during welding. This
is useful if, for example, a component has to be welded using different levels of welding power but the
welding process must not be interrupted.
NOTICE
The jobs must all have the same wire diameter and gas type. It is, however, possible to use e.g. standard
MIG/MAG and adjust the power setting. The job sequence must always be delimited with a free job at
the start and end.
Example: Job 1 – free, Job 2 – MIG 160 A, Job 3 – power 250 A, Job 4 – MIG 100 A, Job 5 – free. In
this example, you can use the "+" and "−" buttons during welding to switch between jobs 2, 3 and 4.
Several such job sequences can be programmed. These must always be separated by a free job. To activate
a job sequence, select a job from this sequence and use the arrow button to call it up. When the torch display
has returned to normal (approx. 3 seconds), you can use the "+" and "−" buttons to switch between the jobs.
NOTICE
If an error occurs in the job sequence (e.g. different gases/material), the sequence cannot be activated.
To switch the "+" and "−" buttons back to their power regulation function, select a free job, e.g. (F 1), in the
"Job" menu and press the arrow button to confirm it.