7 Putting into operation
7.3.5 Downslope and gas post-flow time parameters
You can use the downslope parameter (tap on the Fx button) to set the length of time it takes the welding
current to drop to the minimum current of 15 A after the end of welding. The gas post-flow time is the length
of time during which the gas continues to flow to cool the torch after the end of welding.
7.4
Mains port
Electric shock
Dangerous voltage due to defective cables.
• Check all live cables and connections for proper installation and damage.
• Replace any damaged, deformed or worn parts.
Personal injuries and material damage
Incorrect mains connection can result in personal injuries and material damage.
• Do not mount the components until the mains plug is disconnected.
• Connect the system only to the sockets which have protective earthing conductor.
• Only qualified personnel are permitted to perform work on the device or system.
1
Connect the mains plug to the mains cable as specified on the rating plate. Connect the yellow/green lead
to the protective conductor terminal PE. The three phases (black, brown, and grey) can be connected to L1,
L2 and L3 in any order.
EN - 18
DANGER
DANGER
Insert the mains plug into the corresponding socket.
inoMIG 350/400/500
BA-0014 • 2020-06-05