12 Remote control socket

Tab. 6
PIN
A/1
B/2
C/3
D/4
E/5
F/6
G/7
H/8
J/9
K/10
L/11
M/12
13–17
BA-0014 • 2020-06-05
Remote control socket pin assignment
Name
Description
U-actual
Output signal between 0 V and +10 V. The current welding voltage is
output here in the ratio 10:1 for control purposes.
Example: 40 V welding voltage = 4.0 V signal voltage, input impedance
must be ≥10k Ω. The reference potential is pin 3.
I-actual
Output signal between 0 V and +10 V. The current welding current is
output here in the ratio 100:1 for control purposes.
Example: 100 A welding current = 1 V signal voltage, input impedance
must be ≥10k Ω. The reference potential is pin 3.
GND
Ground (mass) potential for pin 1, 2, 4, 5
Master voltage 2
Input signal for function EC 2
1. A potentiometer (between pin 3 (0 V) and pin 6 (+10 V)) can be
2. A master voltage of between 0 V and max. +10 V can also be
Master voltage 1
Input signal for function EC 1
1. A potentiometer (between pin 3 (0 V) and pin 6 (+10 V)) can be
2. A master voltage of between 0 V and max. +10 V can also be
+10 V
+10 V reference output voltage for potentiometer control pin 4, 5. The
maximum permitted output current is 10 mA.
+24 V
+24 V reference output voltage for the switch signals pin 8, 9, 10.
The maximum permitted output current is 10 mA.
T-BT
Torch trigger input signal for MIG/TIG torch, supply with pin 7. Start
signal for automation.
T up
Input signal of an up/down torch; here the increasing (up) signal, supply
with pin 7.
T down
Input signal of an up/down torch; here the decreasing (down) signal,
supply with pin 7.
Power is flowing
Potential-free make contact. When power is flowing in the machine, this
contact is closed. It is opened as soon as power is interrupted. Maximum
Power is flowing
voltage 48 V, maximum power 1 A.
Free
Not assigned
 More details in the circuit diagram
used here to create and change the control signal.
created (reference potential pin 3).
used here to create and change the control signal.
created (reference potential pin 3).
12 Remote control socket