28. Maintenance and safety check

This unit should be serviced in regular intervals dependent on Operating times and working place conditions.
Before opening the machine switch off the plug!
-
Clean unit inside by vacuum cleaner according to degree of soiling.
Attention:
This Welding unit has to be safety checked every year by JÄCKLE Company or another special qualified
electrician according to the harmonized standard
IEC 60974 – 4
Safety, maintenance and inspection of arc welding equipment in use

29. Remote control socket (Option)

Pin
Name
A / 1
Actual volt-
age
(U-actual)
B / 2
Actual cur-
rent
(I-actual)
C / 3
GND
D / 4
Master (U)-
voltage 2
E / 5
Master (U)-
voltage 1
F / 6
+10V
G / 7
+24V
H / 8
T – BT
J / 9
T – up
K / 10
T – down
L / 11
Current flow
M / 12
Current flow
13-17
free
For more information on the circuit diagram.
Operating manual
Description
Output signal between 0V and +10 V.
The ratio between welding voltage and signal voltage is 10:1.
Example: 40V welding voltage = 4.0V signal voltage
Input impedance should be ≥ 10k. The reference potential is pin 3
Output signal between 0V and +10 V.
The ratio between welding current and signal voltage is 100:1.
Example: 100A welding current = 1V signal voltage
Input impedance should be ≥ 10k. The reference potential is Pin 3
Ground potential for Pin 1, 2, 4, 5
Input signal for the function of EC 2
1) To contact a potentiometer (between pin 3 (0V) and pin 6 (+10 V)).
The output of the potentiometer changes this value.
2) Similarly, a control voltage between 0 V and a maximum of +10 V can be applied
(reference point Pin 3).
Input signal for the function of EC 1
1) To contact a potentiometer (between pin 3 (0V) and pin 6 (+10 V)).
The output of the potentiometer changes this value.
2) Similarly, a control voltage between 0 V and a maximum of +10 V can be applied
(reference point Pin 3).
+10V reference voltage output for potentiometer control Pin 4, 5
The maximum output current is 10mA.
+24V reference output voltage for the switch signals Pin 8, 9, 10
The maximum output current is 10mA
MIG / TIG torch trigger input signal, supply to pin 7
Start signal for automation.
Input signal for an up / down torch, here the increasing (up) signal, supply to pin 7
Input signal for an up / down torch, here the decreasing (down) signal, supply to pin
7
Potential-free contact. If a current flow is detected, the contact is closed.
The contact opens when the current flow is interrupted.
Maximum voltage 48V, maximum current 1A
Not used!