Herunterladen Inhalt Inhalt Diese Seite drucken

Remote Control Socket (Option For This Type Of Machines); Over Temperature - Jackle conMIG 445 Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Wire conveying inside the torch hose pack
Friction resistance of the welding wire inside the wire guide spiral increases in proportion to the length of the hose
pack. Therefore, the torch hose pack shouldn't be any longer than necessary.
When working with aluminium welding wire, it is advised to replace the wire guide spiral with a Teflon wire guide
core. Length of torch hose pack should not exceed 3 m.
After finishing one coil of wire, it is advised to clean both the wire guide spiral and the wire guide tube by air-
blasting.
The gliding quality of the wire guide spiral deteriorates according to the amount of wire conveyed and the
properties of the wire. If wire conveyance becomes unacceptably worse, change the wire guide spiral.

35. Remote control socket (option for this type of machines)

Pin
Name
A / 1
Actual
voltage
(U-actual)
B / 2
Actual
current
(I-actual)
C / 3
GND
D / 4
Master (U)-
voltage 1
E / 5
Master (U)-
voltage 2
F / 6
+10V
G / 7
+24V
H / 8
T – BT
J / 9
T – up
K / 10
T – down
L / 11
Current flow
M / 12
Current flow
13-17
free
For more information on the circuit diagram.

36. Over temperature

When the machine is getting hot during welding, it switched off and it can not be welded, until the machine is
cooled.
In over temperature conditions the following text appears in the displays:
t°C = hot = temperature to high
01 = not used, 02 = Thyristor, 03 = Welding transformer / Choke
Operating manual
Description
Output signal between 0V and +10 V.
The ratio between welding voltage and signal voltage is 10:1.
Example: 40V welding voltage = 4.0V signal voltage
Input impedance should be ≥ 10k. The reference potential is pin 3
Output signal between 0V and +10 V.
The ratio between welding current and signal voltage is 100:1.
Example: 100A welding current = 1V signal voltage
Input impedance should be ≥ 10k. The reference potential is Pin 3
Ground potential for Pin 1, 2, 4, 5
Input signal for the function of EC 1 (only MC 1).
1) To contact a potentiometer (between pin 3 (0V) and pin 6 (+10 V)).
The output of the potentiometer changes this value.
2) Similarly, a control voltage between 0 V and a maximum of +10 V can be applied
(reference point Pin 3).
Input signal for the function of EC 2 (only MC 1).
1) To contact a potentiometer (between pin 3 (0V) and pin 6 (+10 V)).
The output of the potentiometer changes this value.
2) Similarly, a control voltage between 0 V and a maximum of +10 V can be applied
(reference point Pin 3).
+10V reference voltage output for potentiometer control Pin 4, 5
The maximum output current is 10mA.
+24V reference output voltage for the switch signals Pin 8, 9, 10
The maximum output current is 10mA
TIG torch trigger input signal, supply to pin 7
Input signal for an up / down torch, here the increasing (up) signal, supply to pin 7
Input signal for an up / down torch, here the decreasing (down) signal, supply to pin
7
Potential-free contact. If a current flow is detected, the contact is closed.
The contact opens when the current flow is interrupted.
Maximum voltage 48V, maximum current 1A
Not used!
t°C
- 03 -
hot
conMIG 400/445/545
Page 45

Quicklinks ausblenden:

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Conmig 400Conmig 545

Inhaltsverzeichnis