3. Remote control

Handling

The remote control is equipped with the following functions:
1. Arrow buttons
You can set the required temperature gradually to a lower or higher value using the
arrow two buttons
and
.
Note: If the temperature display is set to " -- " with arrow button
ous water heater switches off the heating function.
2. Programme buttons
The two programme buttons
without the need to press the
The factory setting for programme
can assign your own settings for the programme buttons:
• Select the desired temperature with
• To save the current temperature, press the programme button
seconds.

Displayed information

Energy saving mode
The symbol
shows that the appliance works in an energy saving mode, i.e. the
momentary energy consumption is subject to the selected temperature and to the
flow rate in the energy saving mode.
Power limit
If the full output of the instantaneous water heater does not suffice to heat the tapped
quantity of water, this will be indicated by
Operation with preheated water
If the cold water inlet temperature is higher than the set value of the hot water outlet,
the instantaneous water heater will not heat. In this case no power is emitted and the
sun symbol
is displayed.

Safety notes

• At malfunction of the remote control remove the batteries immediately.
• Do not expose the remote control to moisture.
• Flat batteries can leak and damage the remote control. Hence, replace flat batter­
ies right away as soon as battery symbol lights up in the display or the remote con­
trol does not response after keystroke.
• When the remote control is not to be used in the long term, remove the batteries.
• Without working radio connection, the appliance heats to the prior selected set
value.

Battery replacement

Replace the batteries with new AAA­batteries when the battery symbol flashes up.
• Do not use rechargeable batteries!
• Non­rechargeable batteries are not to be recharged.
• Different types of batteries or new and used batteries are not to be mixed.
• When replacing the batteries, observe the correct polarity.

Disposal

Batteries may contain environmentally hazardous substances. Therefore, used bat­
teries must be disposed of at special collecting points and not be mixed with general
household waste.
At the end of the remote control's lifetime, the batteries must be disposed of separate
from the appliance.
41
and
allow to quickly select the preset temperature
and
buttons several times.
is 35 °C and for programme
and
.
on the FX 3­display.
CLAGE
EN
, the instantane-
it is 48 °C. You
or
for min. two