  • DEUTSCH, seite 1
9.2
The PLC configuration key for the I/O zone is module-related. It is printed on the top of the device (4).
4
The sequence of I/O modules starts on the left side of the bus coupler and ends on the left end of the
I/O zone.
The PLC configuration key encodes the following data:
Table 73:
Example: The I/O zone consists of three different modules with the following PLC configuration
keys:
Table 74:
AVENTICS | AES I/O Modules, Analog | R412018147–BAL–001–AG

PLC configuration key for the I/O zone

Number of channels
Function
Type of electrical connection
Abbreviations for the PLC configuration key in the I/O zone
Abbreviati
Meaning
on
8
Number of channels or number of electrical connections; the number always precedes the
element
16
24
DI
Digital input channel
DO
Digital output channel
AI
Analog input channel
AO
Analog output channel
M8
M8 connection
M12
M12 connection
DSUB25
DSUB connection, 25-pin
SC
Spring clamp connection
A
Additional actuator voltage connection
L
Additional logic voltage connection
E
Enhanced functions
P
Pressure measurement
V
Vacuum measurement
D4
Push-in D = 4 mm, 5/32 Inch
Example of a PLC configuration key for the I/O zone
PLC configuration key for the I/O module
8DI8M8
24DODSUB25
2AO2AI2M12A
The left end plate is not reflected in the PLC configuration key.
Conversion of the Valve System
Characteristics of the I/O module
8x digital input channels
8x M8 connections
24x digital output channels
1x D-SUB connection, 25-pin
2x analog output channels
2x analog input channels
2x M12 connections
Additional actuator voltage connection