Herunterladen Inhalt Inhalt Diese Seite drucken

Output Modules; Pressure Measurement Module - Aventics AES Serie Systembeschreibung

Vorschau ausblenden Andere Handbücher für AES Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
AVENTICS | AES I/O Modules, Analog | R412018147–BAL–001–AG
116
LED Diagnosis on the I/O Modules
1
2
3
DIAG
UL
X2U1
Output module 2AO2M12E
1
2
3
DIAG
UL

Pressure measurement module

4P4D4/4VP4D4
8.3

Output modules

The output modules monitor the function of the outputs.
The output module generates an error signal and reports it to the controller if
a diagnostic message from the driver of an output channel is present.
9
Table 71:
Meaning of the diagnostic LEDs on the output modules
Designation
DIAG (1)
– (2)
UL (3)
– (9)
8.4
Pressure measurement module
Pressure measurement modules monitor the sensor voltage in the internal pressure sensors. The
pressure measurement module generates an error signal and reports it to the controller if
the sensor voltage of the internal pressure sensor is outside the error thresholds.
Table 72:
Meaning of the diagnostic LEDs on pressure measurement module 4P4D4/4VP4D4
Designation
DIAG (1)
– (2)
UL (3)
Color
State
Meaning
Red
Illuminate
Diagnostic message of the output module present:
d
Excessive current at the voltage output, or
Insufficient current at the current output, or
Excessive output driver temperature
not assigned
Green
Illuminate
Module supply voltage is present.
d
No function
Color
State
Meaning
Red
Illuminate
Pressure measurement module diagnostic message present:
d
A pressure sensor is defective
not assigned
Green
Illuminate
Module supply voltage is present.