Herunterladen Inhalt Inhalt Diese Seite drucken

After The Completion Of The Fermentation Program - Gram BAKER GA 930 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für BAKER GA 930:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 35

After the completion of the fermentation program

An extra program is built in which begins to cool down the products after the end of
the fermentation process. This stops the fermentation in the products.
Mode of operation and signals
The time after the completion of the program is called tS. When the time tS has
expired, the program section tA begins.
The default value of tS is 10 minutes, but it can be regulated from 0 to 30 minutes.
When the time is set to 0 minutes, the tS program is not active, and the device
continues the fermentation program without pause.
This corresponds to older program versions, such as G 108.
When the tS program is active, the red LED lamp flashes. This is to warn the user of
the extended time for the fermentation process.
When program section tA begins, the cooling system begins to cool the products, and
brings the temperature down to the standard value of +2°C.
Now it is the yellow LED lamp that flashes, to warn that the products have been
through both a normal fermentation process and the extra time tS. The yellow LED
lamp continues to flash until the device is stopped completely. This is done by
pressing the P button.
Interruption of the programs tS and tA
While the program is engaged in either the extended time tS or the actual cooling
phase tA, the user can choose to press either the P or the S button.
Pressing the P button will stop the device completely.
If the S button is pressed, the device will return to the GA program and will continue
to run this.
If the S button is pressed during the extended time or the cooling phase, the red lamp
will glow constantly, and the other lamps will be turned off.
Setting tS and tA
The settings of the two new values can be adjusted via the hidden service menu of
the control system.
Interrupting the automatic program before the program concludes and tS begins
If the user returns to the device before the conclusion of the complete program, the
user can choose to push the S button to cancel the complete program.
The program will now continue its normal functioning with the GA program. For this to
be done, the GA program must have entered the last quarter of its cycle.
Information on the time of completion is removed through this choice, and only the
temperature and humidity are shown, alternately.
The two green lamps and the yellow lamp are also turned off.