01
If this code is displayed, it means that the cabinet temperature sensor has
a short circuit. In the meantime, the cabinet itself will try to maintain the set
temperature. The sensor must be replaced. Request service assistance.
02
If this code is displayed, it means that the cabinet temperature sensor has
been broken. In the meantime, the cabinet itself will try to maintain the set
temperature. The sensor must be replaced. Request service assistance.
03
If this code is displayed, it means that the evaporator temperature sensor
has a short circuit. It means that defrosting of the evaporator will be
interrupted. The sensor must be replaced. Request service assistance.
04
If this code is displayed, it means that the evaporator temperature sensor
has been broken. It means that defrosting of the evaporator will be
interrupted. The sensor must be replaced. Request service assistance.
07
If this code is displayed, it means that the humidity sensor has a short
circuit. It means that humidifying will be interrupted. The sensor must be
replaced. Request service assistance.
08
If this code is displayed, it means that the humidity sensor has been
broken. It means that humidifying will be interrupted. The sensor must be
replaced. Request service assistance.
23
Temperature alarm. The temperature monitoring is factory-set to +/- 10°C
relative to the setpoint. The alarm is triggered, if the upper or lower limit is
exceeded.
40
Steam generator system alarm. This means that an error has occurred in
the steam generator system. Request service assistance.
By pushing the P key, it is possible to view the errors that may have
occurred.
If several errors have appeared, they are shown as F1, F2, etc., - the
display alternates between this indication and the actual error code. (Only
when the cabinet is in stand-by mode).
"clr" is displayed to indicate, if you want to confirm / ignore the error(s).
To confirm / ignore the errors, push the + key. To retain the error
indications, push the – key.

Power failure

During power failure, the control unit remembers all entered program settings and the
clock continues to run. The program therefore proceeds as if nothing had happened.