GB
been refitted. Fit the screw cap
vable with a knife) where the middle hinge
was previously mounted.
Starting up
If during transport the refrigerator/freezer
has been laid down, or if it has been sto-
red in cold surroundings (colder than
+5°C) it must be allowed to stabilise in the
upright position for at least 1 hour before
switching on.
Start the refrigerator/freezer by plugging
the lead into a wall socket.
On connection, an alarm will indicate that it
is too warm and that there has just been a
power failure. See "Alarm" for instruction
on switching off the alarm.
With models having two operating panels,
i.e. one for the refrigeration compartment
and one for the freezing compartment, the
alarm must be deactivated on both panels.

Electronic control

The appliance can be operated with the
two keys "TEMP." and "FREEZE".
By pressing the key and holding it down,
you will in a moment or two see the actual
temperature setting on the display. This
setting will remain on the display for about
3 seconds. By keeping the key pressed
down it is possible to change the setting.
See below.

Temperature setting

The refrigerator/freezer with one control is
factory programmed to run under optimum
conditions at +5°C.
In the refrigerator/freezer with two controls,
the refrigeration compartment is factory
programmed to run at +5°C, the freezing
compartment at -18°C.
All manuals and user guides at all-guides.com
6
(remo-
Changing the
temperature
Press TEMP and keep it held down. You
will in a moment or two see the actual set-
ting on the display and the small lamps will
light up, one after the other, along the
scale. When the end of the scale is rea-
ched all lamps will go out for an instant
before starting to light up again. Release
the TEMP key when the lamp opposite to
the temperature you require lights up. The
refrigerator/freezer will now run at this new
setting.
Freezing down
In refrigerator/freezers with only one con-
trol, the temperature in the freezing com-
partment follows the setting in the refrige-
ration compartment.
If rapid freezing down is required, the cabi-
net must be set to run at the lowest tempe-
rature. This setting affects both refrigerati-
on and freezing compartments, and how
long the setting and the low temperature
are to remain can only be judged by expe-
rience. After goods have been frozen
down, return the setting to normal again.
In models with two controls, activate the
"FREEZE" key to start freezing down.
When freezing down, it is necessary to
choose whether freezing down is to run for
one or for two days (24 or 48 hours). Press
"FREEZE" and hold it down. In a moment
or two you will see the actual setting. At
the same time, in sequence, one, two or
no lamps on the temperature scale will lig-
ht up. The number of green lamps that lig-
ht up indicates the number of freezing-
down days. Release the key when the
required number of days is indicated. The
freezer will now run at this setting. The
small yellow indicator lamp will light up for
as long as the freezing-down process is
running.