5.2 Digital pressure gage
The digital pressure gage has an NiCd battery pack, which when fully charged
provides around 10 hours operating time.
The pressure gage can also be powered from the mains adapter (such as when the
battery pack is flat).
Attention!
Ensure that no damp is able to penetrate the interior!
5.2.1 Front view
1 = Display
2 = On/Off push switch
5.2.2 Rear view
1 = Cable connection
2 = Mains charger connection
5.2.3 Error message
If [ NoSensor ] appears when preparing
a test or during testing, the rail pressure
sensor of the pressure pickup or pressure
pickup module may possibly not be connected
correctly.
In such cases check that the cable is connected correctly to the digital pressure gage
and to the pressure pickup or pressure pickup module, and that there is no open
circuit in the cabling or the connectors.