Herunterladen Inhalt Inhalt Diese Seite drucken

Dimensions Of The Installation Niche; Setting Up As An Stand Alone Appliance - Gaggenau RC 462 Montageanleitung

Vorschau ausblenden Andere Handbücher für RC 462:
Inhaltsverzeichnis

Werbung

Dimensions of the Installation Niche

Setting up as an stand alone appliance

Key:
A
Area for installation of the water connection
The shut off valve for the appliance's water connection is to
be located in the immediate vicinity of the installation niche
such that it is accessible without disassembling the
appliance.
If this is absolutely unavoidable, the shut off valve should be
only be installed in the area of the installation areas labelled
with A and B behind the appliance.
B Area for installation of the electric current
Important!
The upper niche wall must consist of a rigid, load bearing
material (minimum thickness 16 mm). The upper niche wall
must be completely even up to a depth of at least 100 mm
and free from bumps.
Important!
The lateral niche walls must be completely even and free
from bumps. If the niche is formed as a separate part, the
side walls must be completely even up to a depth of at least
100 mm and free from bumps.
Appliance width
457 mm
610 mm
762 mm
D Depth of the installation niche, depending on the
kitchen design (see DESIGN GUIDE)
D = 610 mm minimum!
Note:
The installation niche must have right angles.
The side walls should not exhibit areas that stick out,
projections or unevenness.
X
Y
457 mm
228 mm
610 mm
305 mm
762 mm
381 mm