Water Connection

A cold water connection is necessary for operating the
automatic ice maker. The water pressure must lie
between 1.7 and 10 bar. The installation must
correspond to the local plumbing regulations.
A separate shut off valve should be installed in the
cold water inflow.
The shut off valve should not be located behind the
appliance. It is recommended that you mount the shut off
valve directly next to the appliance or at another place
which is easily accessible.
When installing the water connection, pay attention to the
permissible installation area for the water mains. For
more information concerning the permissible installation
areas, see the section Installation Dimensions".
Note:
The maximum outside diameter of the water mains
(without connecting pieces) is 10 mm.