Herunterladen Inhalt Inhalt Diese Seite drucken

Siemens SINUMERIK 840D sl Handbuch Seite 74

Vorschau ausblenden Andere Handbücher für SINUMERIK 840D sl:
Inhaltsverzeichnis

Werbung

Kanalmenü
6.6 Beispiel: Einstellungen bei 1:N
; a configuration of 3 NCU and a PCU50.
;*******************************************************************
[own]
owner = HMI
;***************************
; ChanMenu
;***************************
[chan HMI]
ShowChanMenu = true
;*******************************************************************
;Channel-groups
;Correlation from channel-group to horizontal softkeys
; -> see config.ini of the TCU
;The section [T2M2N] can also be created in the netnames.ini file
;instead of config.ini file. This configuration applies to all TCU,
;which are not configured by their config.ini.
;*******************************************************************
[T2M2N]
SK1 = CH_GRP_1
SK2 = CH_GRP_2
[CH_GRP_1]
Text = 1. NCU
Member1.Target = 192.168.214.241.192.168.214.1.#1
Member1.Text = NCU1%nKanal 1
Member2.Target = 192.168.214.241.192.168.214.1.#2
Member2.Text = NCU1%nKanal 2
[CH_GRP_2]
Text = 2. NCU
Member1.Target = 192.168.214.241.192.168.214.2.#1
Member1.Text = NCU2%nKanal 1
Member2.Target = 192.168.214.241.192.168.214.2.#2
Member2.Text = NCU2%nKanal 2
Hinweis
Zur Umschaltung einer MCP mit der Bedien-Software darf der PLC-Baustein FB9 nicht
verwendet werden (FB9 darf nicht aktiv sein). Die MCP-Umschaltung muss ggf. im PLC-
Anwenderprogramm realisiert werden.
Lösungsmöglichkeit
Im OB100 (Aufruf des FB1) MCP1BusAdr auf 255 und MCP1Stop auf "true" setzen.
58
Inbetriebnahmehandbuch, 01/2015, 6FC5397-1DP40-5AA2
SINUMERIK Operate (IM9)

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis