Dome configuration

17
Dome configuration
17.1

Open/close dome OSD menu

78
Siemens Building Technologies
Fire Safety & Security Products
Domes which are directly connected to the RS485 interface of the control unit can
also be configured. Data is not output via the COM1A/COM1B interface in
configuration mode, thus preventing double control.
Prerequisites:
The dome is connected to the telemetry interface COM2. See Section 8.7.1:
Control unit with RS485 bus mode or Section 8.7.2: Control unit with TTY bus
mode.
The domes must be equipped with an OSD menu and be suitable for operation
with the control unit.
Prerequisite:
You are logged in as administrator.
1.
Select the desired camera.
2.
In operating mode Telemetry devices directly connected to control unit:
Press the "xxx"-Cam key.
3.
In operating mode Control unit connected to SIMATRIX Terminal-/TTY
connection: Press the keys " xxx"-"Cam" and "yyy"-Mon.
4.
Keep Cam/AX key depressed and press F1.
The OSD menu opens.
Keys
Keep
pressed
Keep
pressed
LED is blinking while dome OSD is activated by Cam+F1 and is not closed by Cam+F10.
Description
Switch on telemetry device operation, and open OSD menu/
CDC050x initialization
Switch off telemetry device operation, and close OSD menu
03.2009