Herunterladen Inhalt Inhalt Diese Seite drucken

Connecting Sistore Mx - Siemens CKA4820 V2 Benutzerhandbuch

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Connection possibilities to the control unit
8.5

Connecting SISTORE MX

28
Siemens Building Technologies
Fire Safety & Security Products
Interface configuration (IVM Terminal Client default)
Baud rate: 9600
Parity:
even
For more information on configuration, see Section 13: Configuring IVM Terminal
Client.
Before connecting the SISTORE MX, please refer to the information in the respective Instruction
Manuals.
Required accessories
RS485 cable: 2-core shielded, maximum permissible length 1.2 km.
9-pin Sub-D plug with housing.
1.
Connect the SISTORE MX (version 2.60 or higher) to the control unit interface
COM1B on the control unit.
2.
Connect the control unit to the power supply unit. See Section 7.3.1: 12 V DC
connection.
Fig. 13
SISTORE MX connected to COM1B
Required settings (SW401) for use of output COM1B as RS232 interface
Fig. 14
Example: Configurations and settings for connection of a SISTORE MX
to COM1B
Interface configuration (these settings must also be made on the SISTORE
MX)
Baud rate: 9600
Parity:
none
For more information on configuration, see Section 14: Configuring SISTORE MX.