MSA501-S(RS485)
SIKONETZ3 interface
6 SIKONETZ3 interface
SIKONETZ3 protocol is a bus communication protocol based on interface
RS485.
Parameters: 19200 baud, no parity, 8 bit, 1 start bit, 1 stop bit
The SIKONETZ3 protocol is built as a master-slave system. The sensor has
only slave function. There are two different lengths of telegrams:
3 Byte:
Address
Byte
6 Byte:
Address
Byte
The address byte is composed as follows:
1
The test byte is generated as XOR-function of the telegram's preceding 2
or 5 bytes.
A0 ... A4: binary coded address 1 ... 31, address 0 is defined for master.
RR: broadcast bit = 1; command is valid for all devices, there will be no
answer to this command.
L: length bit: 1 = short telegram (3 byte); 0 = long telegram (6 byte)
List of commands of the SIKONETZ3 protocol
Column Signification
Hex
TX
RX
S
P
R
MSA501-S(RS485) · Date 06.06.2016 · Art. No. 85614 · Mod. status 152/16
Com-
Check
mand
Byte
Com-
Data
mand
Byte
Low
0
A0 A1 A2 A3 A4 0
Start
Hexadecimal value of the command.
Length of telegram from master to sensor.
Length of telegram from sensor to master.
Transmitted parameter is permanently stored in the sensor.
For this commend it is necessary to bring the device into the
programming mode (command 32h; 33h).
This command can be broadcast.