4.1 CONNECTING THE GAS SUPPLY
Either a G3/8" (manually controlled
controlled appliance) gas connection should be made with a (CE
approved) GI/2" stopcock in the supply pipe, in the chimney.
Be sure that the controls do not get twisted
tension on the controls and the gas line.
Once the gas is connected, check all fittings for leaks.
4.2 PREPARING TO INSTALL THE HEARTH
Note! The hearth
system. However, certain constructional
necessary to install (part of) the Multi-Vent system first.
Please refer to section 7-5: "Installing the Multi-Vent system".
If you use an existing flue:
- you must ensure that you install the special chimney vent unit
before you install the hearth;
- The underside of any decorative beams in the mantle must be
insulated with non-flammable material (e.g. Nobranda)to prevent
the beam from becoming too hot due to the rising heat and the
heat emitted from the convection openings.