3. SAFETY INSTRUCTIONS
The hearth must be installed, connected and checked by an
authorized installer, in accordance with the applicable guidelines for
closed
devices
and the manufacturer's
The installer must ensure that the gas lines and flue gas exhaust
system have no leaks. The chimney must be tested to ensure that it
functions
properly. The regulator and thermostat
checked and a test must be performed to see that the hearth ignites
properly.
Sincethe hearth is a heat-producingdevice, all its surfaces, including
the glass, can become extremely hot 0 100 oc).
The control panel door on the front of the hearth as well as the
control knobs themselves are exceptions. They do not become
excessively hot.
We recommend that you burn the hearth at its highest setting for a
few hours after installing it, ensuring that there is good ventilation,
so that the protective coating inside the hearth has a chance to
evaporate.
Since a hearth is a source of warmth, which circulates the air in a
room, it is important that you not burn the hearth immediately after
renovation;
the natural air circulation
paint fumes and varnish into the combustion chamber, causing them
to accumulate
above
the hearth.
The hearth is set to the nominal load, in accordance with the
category stated on the identification plate, and sealed at the factory.
The pilot light is set to the correct flow. See the technical
this information. Check that the data on the identification plate
corresponds
to the local gas type and pressure. Check that the data
on the identification plate correspond to the type and voltage of the
current in your building.
No combustible material, such as drapes, clothes, laundry, furniture
or any other combustible
hearth.
The
minimum
safe
installation
circuit must also be
will draw moisture and wet
material must be allowed close to the
distance
is 100 cm.
EN
instructions.
data for
EN 5