Operation Instructions for Controller
Zone 1 Compensation Temp. of Cooling
Zone 1 Compensation Temp. of Heating
Zone 2 Compensation Temp. of Cooling
Zone 2 Compensation Temp. of Heating
DHW Compensation Temp.
Swimming Pool Compensation Temp.
Note: Actual target temperature of system=Set target temperature of controller + Compensation temperature
③ System installation
Tap "SYSTEM INSTALLATION" icon in Picture 22 to enter the system control parameters setting interface. You can set
the operating parameters for the system.
Function
Control Mode of Zone1
Control Mode of Zone2
Control Mode of DHW
Control Mode of Pool
Zones Water Temp. Control Mode
Auxiliary Heat Source
Outdoor Temp. for (Heat to Cool)
Outdoor Temp. for (Cool to Heat)
Max Temp DHW with HP only
Ambient Temp. of Heating Off
△ T for Heating On
(△ T=Tset-Two)
Function
Main controller, Third party controller, Thermostat
Main controller, Third party controller, Thermostat
Main Controller, Third Party Controller
Main Controller, Third Party Controller
Direct, Auto curve, Set curve
Electric Heating&Boiler, Electric Heating, Boiler
Picture 24
Parameter Range
-15~15°C
-15~15°C
-15~15°C
-15~15°C
-15~15°C
-15~15°C
Picture 25
Parameter Range
0~30°C
0~30°C
30~55°C
5~35°C
0~15°C
57
Default
0°C
0°C
0°C
0°C
0°C
0°C
Default
Main controller
Main controller
Main Controller
Main Controller
Direct
Electric Heating
15°C
10°C
45°C
27°C
6°C