Herunterladen Diese Seite drucken

Device-Status Monitor Power-Supply; Device-Status Trap - Hirschmann Hios-2S Rspe Referenzhandbuch

Rail switch power enhanced
Device Monitoring
no device-status monitor ring-redundancy
Disable the option
Mode: Global Config Mode
Privilege Level: Administrator
Format: no device-status monitor ring-redundancy

12.1.7 device-status monitor power-supply

Enable or disable monitoring the condition of the power supply(s).
Mode: Global Config Mode
Privilege Level: Administrator
Format: device-status monitor power-supply <P-1>
Parameter Value
1..2
P-1
no device-status monitor power-supply
Disable the option
Mode: Global Config Mode
Privilege Level: Administrator
Format: no device-status monitor power-supply <P-1>

12.1.8 device-status trap

Configure the device to send a trap when the device status changes.
Mode: Global Config Mode
Privilege Level: Administrator
Format: device-status trap
RM CLI HiOS-2S RSPE
Release 6.1 09/2016
Meaning
Number of power supply.
12.1 device-status
179