Clock

9.1
clock
Configure local and DST clock settings.
9.1.1

clock set

Edit current local time.
Mode: Global Config Mode
Privilege Level: Administrator
Format: clock set <P-1> <P-2>
Parameter Value
YYYY-MM-DD
P-1
HH:MM:SS
P-2
9.1.2

clock timezone offset

Local time offset (in minutes) with respect to UTC (positive values for loca-
tions east of\nGreenwich).
Mode: Global Config Mode
Privilege Level: Administrator
Format: clock timezone offset <P-1>
Parameter Value
-780..840
P-1
138
Meaning
Local date (range: 2004-01-01 - 2037-12-31).
Local time.
Meaning
Edit the timezone offset (in minutes).
9.1 clock