59.1 rmon-alarm

Create a RMON alarm action.

59.1.1 rmon-alarm add

Add RMON alarm.
Mode: Global Config Mode
Privilege Level: Operator
Format: rmon-alarm add <P-1> [mib-variable <P-2>]
[rising-threshold <P-3>] [falling-threshold <P-4>]
[mib-variable]: MIB variable
[rising-threshold]: Rising threshold
[falling-threshold]: Falling threshold
Parameter Value
1..150
P-1
string
P-2
1..2147483647
P-3
1..2147483647
P-4
634
Meaning
Enter an index that uniquely identifies an
entry in the alarm table.
Enter an object identifier of the particular
variable to be sampled, max. 32 characters.
Enter the rising threshold for the sampled
statistic.
Enter the falling threshold for the sampled
statistic.