Herunterladen Diese Seite drucken

Port-Monitor; Port-Monitor Condition Crc-Fragments Interval; Port-Monitor Condition Crc-Fragments Count - Hirschmann Hios-2S Rspe Referenzhandbuch

Rail switch power enhanced
Port Monitor

53.2 port-monitor

Configure the Port Monitor condition settings.
53.2.1 port-monitor condition crc-fragments
interval
Configure the measure interval in seconds (5-180s) for CRC-Fragment
detection. Default 10.
Mode: Interface Range Mode
Privilege Level: Operator
Format: port-monitor condition crc-fragments interval
<P-1>
Parameter Value
5..180
P-1

53.2.2 port-monitor condition crc-fragments count

Configure the CRC-Fragment counter in parts per million (1-1000000 [ppm]).
Default 1000 [ppm].
Mode: Interface Range Mode
Privilege Level: Operator
Format: port-monitor condition crc-fragments count <P-1>
Parameter Value
1..1000000
P-1
RM CLI HiOS-2S RSPE
Release 6.1 09/2016
Meaning
Enter a number in the given range.
Meaning
Enter a number in the given range.
53.2 port-monitor
571

Kapitel

loading