Herunterladen Diese Seite drucken

Ptp; Ptp Operation; Ptp Clock-Mode - Hirschmann HiOS-2S RSPE Referenzhandbuch

Rail switch power enhanced

Werbung

Precision Time Protocol (PTP)

56.1 ptp

Enable or disable the Precision Time Protocol (IEEE 1588-2008).

56.1.1 ptp operation

Enable or disable the Precision Time Protocol (IEEE 1588-2008).
Mode: Global Config Mode
Privilege Level: Administrator
Format: ptp operation
no ptp operation
Disable the option
Mode: Global Config Mode
Privilege Level: Administrator
Format: no ptp operation

56.1.2 ptp clock-mode

Configure PTPv2 (IEEE1588-2008) clock mode. \nIf the clock mode is chan-
ged, PTP will be initialized.
Mode: Global Config Mode
Privilege Level: Administrator
Format: ptp clock-mode <P-1>