Device Monitor
no device-status monitor envm-removal
Disable the option
Mode: Global Config Mode
Privilege Level: Administrator
Format: no device-status monitor envm-removal
10.1.4

device-status monitor envm-not-in-sync

Enable or disable monitoring synchronzation between the external non-vola-
tive memory\n and the running configuration.
Mode: Global Config Mode
Privilege Level: Administrator
Format: device-status monitor envm-not-in-sync
no device-status monitor envm-not-in-sync
Disable the option
Mode: Global Config Mode
Privilege Level: Administrator
Format: no device-status monitor envm-not-in-sync
10.1.5

device-status monitor ring-redundancy

Enable or disable monitoring if ring-redundancy is present.
Mode: Global Config Mode
Privilege Level: Administrator
Format: device-status monitor ring-redundancy
no device-status monitor ring-redundancy
Disable the option
Mode: Global Config Mode
Privilege Level: Administrator
Format: no device-status monitor ring-redundancy
10.1.6

device-status monitor power-supply

Enable or disable monitoring the condition of the power supply(s).
Mode: Global Config Mode
Privilege Level: Administrator
Format: device-status monitor power-supply <P-1>
Parameter Value
1..2
P-1
120
Meaning
Number of power supply.