Inlinepower Priority; Inlinepower Fast-Startup - Hirschmann Hios-2S Rspe Referenzhandbuch

Rail switch power enhanced
Power Over Ethernet (PoE)

52.2.7 inlinepower priority

Configure the inline power priority for this interface. In case of power scarcity,
inline power on interfaces configured with the lowest priority is dropped first.
Possible values are: critical, high or low, default: low. The highest priority is
critical.
Mode: Interface Range Mode
Privilege Level: Operator
Format: inlinepower priority <P-1>
Parameter Value
crit.
P-1
high
low

52.2.8 inlinepower fast-startup

Enable or disable fast startup.
Mode: Interface Range Mode
Privilege Level: Operator
Format: inlinepower fast-startup
no inlinepower fast-startup
Disable the option
Mode: Interface Range Mode
Privilege Level: Operator
Format: no inlinepower fast-startup
564
Meaning
Set this interfaces' inline power priority
to critical (highest).
Set this interfaces' inline power priority
to high.
Set this interfaces' inline power priority
to low. This is the default setting.
52.2 inlinepower