Herunterladen Diese Seite drucken

RK Rose+Krieger RK MonoLine R Montageanleitung Seite 99

Lineareinheit
Vorschau ausblenden Andere Handbücher für RK MonoLine R:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Positioning clamping bars
Fig. 15: Positioning clamping bars
Fixing clamping bars
Fig. 16: Fixing clamping bars
A Distance between fixing holes
B Required space
5.3.2 Assembling a linear unit with slot stones
Applicable to
Linear unit RK MonoLine R/RK MonoLine Z/RK MonoLine Z corrosion-protected
27.10.2023
Assembling the linear unit on the substrate > Assembling a linear unit with slot stones
2.
Ensure that a distance of 300 mm between the clamping bars
(Fig. 15/1) is not exceeded at maximum load.
3.
Tighten two screws (Fig. 16/1) for each clamping bar
(Fig. 16/2).
For this, observe the following:
Size
A [mm] B [mm] Screw size Tightening
40
52
60
80
80
100
120
140
ð The linear unit is installed on the substrate.
Version
RK MonoLine R, Z, Z
Size
40/60/80/120
65
M6
100
M8
120
M8
160
M8
Assembly
torque [Nm]
10
25
25
25