Assembly
Assembling the linear unit on the substrate > Assembling the linear unit with clamping bars
5.2 Conditions at the installation site
5.3 Assembling the linear unit on the substrate
5.3.1 Assembling the linear unit with clamping bars
Applicable to
Inserting clamping bars
Fig. 14: Inserting clamping bars
Linear unit RK MonoLine R/RK MonoLine Z/RK MonoLine Z corrosion-protected
98
The following conditions must be met at the linear unit's installation
site:
n
The substrate and the mounting surfaces are designed for
static and dynamic loads.
The installation site has a smooth floor area, is free from vibra-
n
tions, oscillations or shocks, and is moisture-resistant.
n
Sufficient lighting is available.
n
The installation site is clean and dry, and free from dust and
objects.
n
The atmosphere must be free from solvents.
n
All of the connections required on site are available.
Room temperature: 0 - 60°C
n
n
Relative humidity:
RK MonoLine Z, R: 0 - 85%
RK MonoLine Z
n
Temperatures below the dew point are not permitted (excep-
tion: RK MonoLine Z
Version
RK MonoLine R, Z, Z
Size
40/60/80/120
Personnel:
Protective equipment:
Prerequisite:
The substrate must be prepared for the linear unit being fixed
n
to it.
1.
Insert clamping bars (Fig. 14/1) into the slot of the guide
profile.
Depending on the length of the linear unit, 2
or more clamping bars must be inserted on
each side of the guide profile (Fig. 14/2).
: 0 - 95%
).
n
Assembly staff
n
Protective clothing
n
Protective gloves
n
Safety shoes