5.4.4 Assembling the limit switch
5.4.4.1
Assembling the mechanical limit switch
Applicable to
Assembling the actuator
Fig. 35: Assembling the actuator
Assembling the limit switch
Fig. 36: Assembling the limit switch
Linear unit RK MonoLine R/RK MonoLine Z/RK MonoLine Z corrosion-protected
27.10.2023
Assembling optional modules > Assembling the limit switch
Version
RK MonoLine R, Z
Size
40
Personnel:
Protective equipment:
Prerequisite:
n
The electric gear unit and/or motor (if available) are secured
against restarting.
1.
Insert and position the slot stones (Fig. 35/1) in the slot of the
guide carriage.
2.
Place the actuator (Fig. 35/2) at the height of the inserted slot
stones.
3.
Tighten 2 screws (Fig. 35/3):
Size
Screw size
40
M4
4.
Insert and position the slot stones (Fig. 36/1) in the slot of the
guide profile.
5.
Place the limit switch (Fig. 36/4) along with a mounting
bracket (Fig. 36/3) at the height of the inserted slot stones.
6.
Tighten 2 screws (Fig. 36/2):
Size
Screw size
40
M4
ð The limit switch is assembled.
n
Assembly staff
n
Protective clothing
Protective gloves
n
n
Safety shoes
Tightening torque [Nm]
2
Tightening torque [Nm]
2.1
Assembly